Sign In | Join Free | My carsrow.com
China DONGGUAN LONROY EQUIPMENT CO LTD logo
DONGGUAN LONROY EQUIPMENT CO LTD
DONGGUAN LONROY EQUIPMENT CO LTD
Verified Supplier

2 Years

Home > Environment Test Chamber >

Environmental Climate Two Boxes Hot and Cold Impact Testing Chamber

DONGGUAN LONROY EQUIPMENT CO LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Environmental Climate Two Boxes Hot and Cold Impact Testing Chamber

Type : Testing Machine

Accuracy Class : High Accuracy

Accuracy : ±0.5%

Brand Name : LONROY

Place of Origin : Guangdong, China

Application : Auto Testing, Laboratory Testing, Lab Testing

customized support : OEM, ODM, OBM

power : ----

Protection Class : IP57

Voltage : 220 V

warranty : 1 Year

MOQ : 1

Contact Now

Environmental Climate Two Boxes Hot And Cold Impact Testing Chamber

Product Name: two-box cold and hot impact test box

Product Model: KB-TC-80

Environmental Climate Two Boxes Hot And Cold Impact Testing Chamber

Product Brief Introduction:

Scope of application

This series of cold and heat shock test box is suitable for alternating shock test of electrical and electronic products and electronic parts.

Applicable standard

Products can meet CNS, MIL, IEC, JIS, GB/T2423.5-1995, GJB150.5-87 and other standards

Control Mode:

Using low temperature and high temperature hot and cold storage tank, in accordance with the action to open the valve, the low temperature and high temperature to test by air supply system fast fast groove, so as to achieve rapid temperature shock effect, balance (BTC) + special temperature control system design of supply air circulation system, to control SSR P.I.D. way, make the system of heat equal to the amount of heat loss, thus the use of long-term stability.


Environmental Climate Two Boxes Hot And Cold Impact Testing Chamber

Technical Parameters:

Temperature impact range

High temperature 60℃~+150℃


Low temperature -40℃~-10℃

Preheating temperature range

+60℃ ~ +180℃

High temperature tank heating time

RT(indoor temperature)~+180℃ takes about 40min

(room temperature is +10 ~ +30℃).

.

Pre-cooling temperature range

-10℃~-55℃

Cooling time of cryogenic tank

RT (room temperature) ~ -55℃ for about 50min (room temperature +10-- +30℃)

Temperature fluctuation

±1.0℃

Temperature Uniformity

±2.0℃

Impact recovery time

-40-- +150℃ for 5min.

The high and low temperature impact constant temperature time is above 30min

Environmental Climate Two Boxes Hot And Cold Impact Testing Chamber

Product Mix:


Inside Dimension

W500×H400×D400 mm


Carton Size

W1230×H2250×D1700 mm

In the cases of material

Fogged stainless steel plate(SUS#304)

Carton material

Sand-lined stainless steel plate(SUS#304)

Heat preservation material

a.

High temperature tank: aluminum silicate insulation cotton.

b.

Low temperature tank: HIGH density PU foam.

Door

Upper and lower monolithic doors, open on the left.

a. Embedded flat handle.

b.After the button:SUS#304.

c.Silicone foam rubber strip.

Testing rack

a.The hanging basket size:W500 x D400mm.

b.No more than 5KG.

c.Stainless steel SUS304 inner case..


Heating system

Finned radiator type stainless steel heater.

1.High temperature tank 6 KW.

2.Cryostat 3.5 KW.

Air circulation system

1.Motor 1HP×2 Platform.

2.Stainless steel extension shaft..

3.Multi-wing fan blade(SIROCCO FAN).

4.Specially designed fan forced air circulation system.


Refrigeration System:

Adopt multi - section automatic load capacity adjustment technology, more efficient, more energy - saving

Pressure reduction machine

Imported French "Taikang" brand semi-enclosed compressor

Cold condenser

Fin - mounted cooling fan

Hair steamer

Finned multi - segment automatic load capacity adjustment

Bulk expansion valve

Imported from Danfoss, Denmark

Refrigerant

R404A imported from USA

Make cooling auxiliary parts

Desiccant (Denmark), oil separator (USA), refrigerant window (Denmark), solenoid valve (Japan), filter (Japan), pressure controller (Korea), globe valve (Italy) and other refrigeration parts are imported

Protector:

Zero crossing brake fluid power controller

Heating air burn protection switch

Compressor overpressure protection switch

Compressor overload overcurrent protection switch

Phase loss protection switch

No fuse overload protector

Quick heating insurance

Master Controller:

Touch-screen direct button controller, Chinese and English 7 "graphics wide view, high contrast with adjustable backlight function of large LCD LCD controller.

1.Controller specification:

a. Precision: temperature ±0.1℃+1digit.

b. Resolution: temperature ±0.1.

c. It has upper and lower standby functions and alarm functions.

d. Temperature input signal T-type.

e.P.I.D control parameter setting,P.I.D automatic calculation.

2.Screen display function:

a. Screen chat, no need to press the button to enter, direct touch screen options.

b. Direct display of temperature setting (SV) and actual (PV) values.

c. Display the fault status and explain the troubleshooting method.

d. Display the current program number, duration, remaining time and number of cycles.

e. The setting value of temperature program is displayed by graph curve, with the function of real-time display program curve execution.

f. With a separate program editing screen, temperature, time and cycle times can be entered.

g. The screen can be backlit.

h. Screen display protection can be used for timing, TIMER or manual off Settings.

3. Program capacity and control function:

a. Available program group: maximum 96 PATTEN(i.e. 96 test specifications can be set).

b. Repeatable execution of commands: each command can be executed 999 times.

c. Ments time setting 0--99Hour59Min.

e. It has the memory of power off program, and automatically starts and continues the program function after power back on.

f. Real-time display of graphic curves during program execution.

g. Reservation startup and shutdown functions.

h. With date and time adjustment functions.

Primary Clustering:

1.Ac contactor: France

2.Thermal relay: France

3.Ac relay: France

4.Time relay: France

5.Controller: Independently developed

6.Overtemperature protector: Taiwan

7.Power master switch: Taiwan

8.Solid state relay: Taiwan,

9.Button switch: Taiwan

10.Dry burn protector: Italy

Supplementary Instruction:

Make the electric voltage: AC3 5W 380V 50/60Hz.

Voltage variation allowable: ±10% of the fixed voltage.

Environment:

Allowed environment: 0 ~ 30℃

Performance assurance environment: 5 ~ 25℃

Do not place other objects within 60CM around the instrument

Items not included in the appraisal:

1. Preparatory work for the establishment of the site

2. Electrical equipment on the input side

3. Electrical wiring on the input side

Environmental Climate Two Boxes Hot and Cold Impact Testing ChamberEnvironmental Climate Two Boxes Hot and Cold Impact Testing ChamberEnvironmental Climate Two Boxes Hot and Cold Impact Testing ChamberEnvironmental Climate Two Boxes Hot and Cold Impact Testing ChamberEnvironmental Climate Two Boxes Hot and Cold Impact Testing ChamberEnvironmental Climate Two Boxes Hot and Cold Impact Testing ChamberEnvironmental Climate Two Boxes Hot and Cold Impact Testing Chamber


Product Tags:

hot and cold testing chamber

      

environmental impact test chamber

      

two-box climate testing chamber

      
 Environmental Climate Two Boxes Hot and Cold Impact Testing Chamber Manufactures

Environmental Climate Two Boxes Hot and Cold Impact Testing Chamber Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DONGGUAN LONROY EQUIPMENT CO LTD
*Subject:
*Message:
Characters Remaining: (0/3000)